#1 Stacja lutownicza LY IR6000


by wojtas87 18 November 2018, 11:05
Cześć.

Szybkie pytanie odnośnie stacji z tematu. Czy górny promiennik podczerwieni powinien posiadać wbudowaną termoparę?

Może od razu wyjaśnię o co mi chodzi. Otóż nurtuje mnie fakt, iż w sterowniku PC410 ustawia się parametr Hb, który oznacza maksymalną temperaturę górnego promiennika. U mnie jednak nie ma fizycznie termopary w górnym promienniku, więc element ten rozgrzewa się do czerwoności. Nie powinno tak być i chciałbym się dowiedzieć czy producent zrobił to celowo, czy poprzedni właściciel stacji (kupiłem używaną) przy niej majstrował. Skąd sterownik ma wiedzieć aktualnie jaką temperaturę osiąga "góra"?

Re: Stacja lutownicza LY IR6000


by Google Adsense [BOT] 18 November 2018, 11:05

#2 Re: Stacja lutownicza LY IR6000


by matic 18 November 2018, 12:45
wojtas87 wrote:Czy górny promiennik podczerwieni powinien posiadać wbudowaną termoparę?
Hello!
No, there is no thermocouple on the top heater.

wojtas87 wrote:Skąd sterownik ma wiedzieć aktualnie jaką temperaturę osiąga "góra"?
The top heater is controlled by Altec PC410 controller. In this controller are special "PID (Proportional–Integral–Derivative)" settings, which are set by the factory of rework machine.
The temperature of the top heater depends on this settings, which are specially tuned for each type of top heater.

You can access to these settings by holding the PAR/SET button for cca 4 seconds. Press the same button to switch between the individual settings.
I suggest you to write down each setting before you change anything.

#3 Re: Stacja lutownicza LY IR6000


by wojtas87 18 November 2018, 14:33
Yes, You are right but the PID algorithm it is not directly related with the temperature of the upper heater. It is with a thermocouple and selected profile. If ramp parameter rise, the controller turns ON the upper heater with 100% of power so it`s become red hot. If there would be a thermocouple in the upper heater it would warm up to the set temperature in Hb parameter of a PC410. Am I wrong?

#4 Re: Stacja lutownicza LY IR6000


by matic 18 November 2018, 16:00
The top heater is controlled according to the PID settings, temperature detected by the main thermocouple and of course the set profile.
The PID settings are tuned according to the expected temperature of the PCB board, which is detected by the main thermocouple.

#5 Re: Stacja lutownicza LY IR6000


by wojtas87 18 November 2018, 17:57
Yes. but without thermocouple in the top heater it operates always with 100% of power. It is unsafe for a chip.

So how to connect a thermocouple for UH (Uppper heater) control?

#6 Re: Stacja lutownicza LY IR6000  [SOLVED]


by matic 18 November 2018, 18:31
wojtas87 wrote:Yes. but without thermocouple in the top heater it operates always with 100% of power. It is unsafe for a chip.
Actually not.
It runs at 100% of power, until the temperature detected by main thermocouple (PV value) rises close to the target temperature (SV value). When this happens, the PC410 disables the upper heater and controls it with short pulses only to maintain the target temperature.

#7 Re: Stacja lutownicza LY IR6000


by wojtas87 19 November 2018, 08:38
OK, You convincent me that the solution can work properly but the Hb parameter is bullshit on this machine.

Re: Stacja lutownicza LY IR6000


by Google Adsense [BOT] 19 November 2018, 08:38

Who is online

Users browsing this forum: No registered users and 3 guests

_______________________________
All rights reserved. Unauthorised copying of this website's content or any of its part is strictly forbidden.
Any trademarks, brand names, products or services published on this website belong to their legal owners, are copyrighted and used for information purposes only.